Offices · Schools · Public buildings

Commercial and public buildings

Air tightness tests on large buildings, with several fans when the volume requires it: offices, schools and after-school centres, secondary schools, sports facilities, healthcare buildings and public buildings, in the Bas-Rhin and the Grand Est region.

Since 1st July 2022, the French RE2020 regulation has applied to offices and educational buildings. Air permeability becomes a result to be justified at the end of construction, on buildings whose construction methods were never designed for this constraint.

Request a quote Offices in detail

Airtightness test on a large building

RE2020: testing becomes mandatory in commercial buildings

New offices. Every office building with a reference floor area of up to 3,000 m² must justify its air permeability by a measurement, with a reference value of 1.7 m³/(h.m²) of heat-loss envelope area excluding the ground floor. Above 3,000 m², the measurement remains possible and is often requested by building owners: it makes it possible to take the actual performance of the building into account rather than a default value.

Schools, after-school centres and public buildings. The measurement is very often required in the specifications or requested by the local authority, to check the value used in the thermal study and deliver a comfortable, energy-efficient building.

The trap: site teams often discover air tightness at the time of the final test, when linings, suspended ceilings and windows are already installed. At that stage, every leak is expensive to fix. We describe the typical weak points on our page commercial buildings and offices.

Our method for large buildings

  • Upfront analysis: value used in the thermal study, volume to be measured, risk areas identified on the drawings.
  • Intermediate test on the whole building or on a sample area, before linings and suspended ceilings: we measure, locate the leaks with the contractors, and corrections are made while they are still simple.
  • Final test at handover, with several fans running simultaneously on large volumes (over 100,000 m³ in our references), and a report for the completion file.
  • Leak detection by ultrasound and infrared thermography, and air tightness testing of ductwork.

Our commercial and public building references

Hospitals, schools, secondary schools, sports complexes, administrative headquarters: some of the buildings we have tested in Alsace and the Grand Est region.

Multi-fan air permeability test on a large building

Graffenbourg Hospital - Brumath

Air permeability tests of the envelope.

Floor area: 1754 m²

Volume: 5263 m3

Request a quote
Airtightness test of a school and after-school centre

Nursery school and after-school centre - Gambsheim

 

Air permeability tests of the envelope.

Floor area: 1330 m²

Volume: 4392 m3


Request a quote

Airtightness test of a commercial building

Niederhausbergen sports complex

Air permeability tests of the envelope.

Floor area: 1940 m²

Volume: 12223 m3


Request a quote

University of Strasbourg staff centre

Air permeability tests of the envelope and ventilation ducts.

Floor area: 1457.10 m²

Volume: 5932 m3

Request a quote

University of Strasbourg staff centre, airtightness test
Hospitality training centre, air permeability test

Hospitality centre of excellence, Illkirch-Graffenstaden

Air permeability tests of the envelope and ventilation ducts.

Area: 2179.20 m²

Volume: 9960 m3


Request a quote

SDEA headquarters, Schiltigheim

Air permeability test.

Area: 7200 m²

Volume: 27153 m3


Request a quote

SDEA headquarters, airtightness test
Building in Duppigheim, airtightness test

Duppigheim school and after-school centre

Air permeability test and ultrasound survey.

Area: 1788.30 m²

Volume: 6347 m3


 Request a quote

CAF du Bas-Rhin 

Air permeability test and ultrasound survey.

Floor area: 10262 m²

Volume: 28314 m3


Request a quote

CAF du Bas-Rhin, air permeability test
School, airtightness test

Souffelweyersheim after-school centre


Air permeability test.

Area: 1786 m²

Volume: 2853 m3


Request a quote

INET-CNPT 

Air permeability test.

Area: 5541 m²

Volume: 18804 m3

Request a quote

INET CNFPT Strasbourg, airtightness test
Large building tested by Exp’Air 67

Le Corbusier building trades high school 

Air permeability test.

Area: 14580 m²

Volume: 102659 m3


Request a quote

Northern Alsace public health establishment (EPSAN)

Air permeability test.

Area: 9775 m²

Volume: 36924 m3

Request a quote

EPSAN Strasbourg, air permeability test
Building in Montbéliard, airtightness test

Montbéliard school and after-school centre

Air permeability test.

Area: 1604 m²

Volume: 2958 m3


Request a quote